I must have gotten pale when some festival organizer handed me the end of a cable with a male plug. ‘Your electricity supply, here you go!’
Me: ‘… ???’
Organizer, still waving the cable end around: ‘Just use an adapter!’ (he barely managed to omit the ‘stupid woman’ in his answer …)
kersploosh@sh.itjust.works 2 months ago
The last extension cord you will ever need.
Image
lime@feddit.nu 2 months ago
at least it’s short enough that it will only reach two plugs on the same panel, thereby guaranteeing that the first things that blow are breakers.
terranoid@lemmy.cafe 2 months ago
Yeah, not what I need. I need NEMA 5-15 to CAT6 adapter
_druid@sh.itjust.works 2 months ago
Alternatively, One can plug one end in, then you have a creative new way to parent.
“Didn’t mow the lawn? C’mere Billy, hold out your palm.”
CoopaLoopa@lemmy.dbzer0.com 2 months ago
Unless one of your outlets is wired backwards, plugging this into 2 outlets on the same side of your electrical panel won’t do anything.
If you were able to plug it into outlets on different sides of your panel, then you just created a 240v short and the cable is going to be real-spicy real-quick.
Venator@lemmy.nz 2 months ago
Unless you accidentally touch one if the prongs after plugging one end in… 😅
JasonDJ@lemmy.zip 2 months ago
Would that only happen if one outlet were wired backwards (hot to neutral and vice-versa)?
If both outlets are wired correctly, as I’m envisioning it, the extension cord is parallel to the existing branch.
Same if both outlets are wired (the same) incorrectly.
But if one outlet is wired correctly and one has its poles swapped, then you are shorting hot directly to neutral…
But also being a 3-prong outlet…assuming everything is wired correctly…the short would either be redirected to ground and either trip the breaker or trigger a GFCI…no?
IANAElectrician. Just a high dude thinking about circuits.
Lemmyoutofhere@lemmy.ca 2 months ago
Laughs in generator.
SapphironZA@sh.itjust.works 2 months ago
You are forgetting the plug on the knob that will plug it in
uen3@sh.itjust.works 2 months ago
Even better: Image
agamemnonymous@sh.itjust.works 2 months ago
Is this the one you use to feed the house from a generator? If so, I think that’s the one time it’s valid
JasonDJ@lemmy.zip 2 months ago
The lovely suicide cord.
Worth mentioning that it is plenty safe…if used appropriately (for attaching a generator to a house that doesn’t have an inlet).
It’s when it’s not used appropriately that’s a problem. And it’s very easy to not use it appropriately.
Bad_Ideas_In_Bulk@lemmy.world 2 months ago
Murphy’s law says it will be used wrong, and as such it is a bad design and a bad idea.
expatriado@lemmy.world 2 months ago
i guess if you’re got a bad breaker on your panel, you can load 2 circuits on one breaker with that thing, at least until the hardware store opens. you still get overcurrent protection… but a very unlikely thing to need